fbpx
January 9, 2025

Moldex® 7000/9000 Series EasyLock® Bayonet To 40MM NATO (RD40x1/7) Adapter

large_preview_MOLDEX_BAYONET_TO_40MM_NAT

Moldex® 7000/9000 Series EasyLock® Bayonet To 40MM NATO (RD40x1/7) Adapter

This prototype design for a Moldex® 7000/9000 series EasyLock® bayonet respirator to 40 MM NATO, gas mask thread adapter. This adapter makes the Moldex® 7000/9000 series line compatible to RD40x1/7 threaded filter canisters or step down adapters to enable greater cross compatibility of respirators and filters to other manufacturer models.

If you do not have access to 40MM (RD40x1/7) filters, you can use the following adapters to step down to COTS filter cartridges from these companies below:

40 MM NATO to 3M™ Bayonet Adapter
https://www.thingiverse.com/thing:4245358

40 MM NATO to MSA® Bayonet Adapter
https://www.thingiverse.com/thing:4265715

40MM NATO to MSA® Comfo Classic Adapter
https://www.thingiverse.com/thing:4267676

40MM NATO to Honeywell/Honeywell North® Adapter
https://www.thingiverse.com/thing:4268775

40MM NATO to Honeywell Sperian® Filter Adapter
https://www.thingiverse.com/thing:4297348

40MM NATO to AOSafety® Threaded Adapter
https://www.thingiverse.com/thing:4273365

40 MM NATO to AOSafety® R5700 8051 Bayonet Adapter
https://www.thingiverse.com/thing:4265538

40MM NATO to Portwest® Bayonet Adapter
https://www.thingiverse.com/thing:4273464

40MM NATO to Moldex® 7000/9000 Series EasyLock® Bayonet Adapter
https://www.thingiverse.com/thing:4275446

40MM NATO to Secura BC Bayonet Adapter
https://www.thingiverse.com/thing:4294187

40MM NATO to JSP® Force™8 Filter Adapter
https://www.thingiverse.com/thing:4294203

Alternatively, if you cannot source COTS filters, search thingiverse, there are a number of other DIY filter cartridge designs to mate to other major manufacturer, 3M/MSA/etc. respirator’s attachment system.

Part Description:

MOLDEX_BAYONET_TO_40MM_NATO_ADAPTER_GEN1.stl

Initial model release.

Disclaimers/Risks:

1.) Requires 40 mm OD gasket or o-ring on the interior RD40x1/7 pocket to ensure proper seal maintained between cartridge and threads.

2.) 3D printing materials are not resistant to many solvents, are water soluble, and degrade when exposed to chemicals. 3D printing this adapter is only a temporarily ad-hoc solution against biological threats. Once supply chain return to normal users should purchase OEM OSHA/NIOSH/EN standard approved adapters and respirator accessories.

Dev. Notes:

04/23/2020 – Initial model release. I do not have Moldex® 7000/9000 series respirators or filters to check measurements, so I extrapolated based on the male side bayonet geometry. Please report back in comments for any fitment issues and I’ll release revisions as required.

Credits:

Thanks to namrow’s Moldex® 9400 ABEK1 Cartridge Valve Adapter design that allowed me to pull reference Moldex® bayonet dimensions to extrapolate female side geometrical interface.

This article was first featured at https://ift.tt/2Y2bXuz on April 23, 2020 at 05:30PM by AgapeModeling

%d bloggers like this: